Enacted by congress on july 26 1990 the ada provides certain legal rights to americans with disabilities including protection from discrimination based on their.
Ada shower bench requirements.
Ada thresholds with all manufactured shower systems the installation has to bring the floor to within 0 5 of the top of the threshold to be ada compliant and comply with the following.
The depth of a removable in tub seat shall be 15 inches 380 mm minimum and 16 inches 405 mm maximum.
Although many tiled showers include a built in seat to meet ada regulations these seats must be between 17 and 19 inches from the shower floor and extend the full depth of the stall.
Ada requirements state there must be 36 clearance on all usable sides of the table this measurement is taken from the back edge of the bench.
In standard roll in type shower compartments the controls faucets and shower spray unit shall be located above the grab bar but no higher than 48 inches 1220 mm above the shower floor.
Where a seat is provided the controls faucets and shower spray unit shall be installed on the back wall adjacent to the seat wall and shall be located 27 inches 685 mm maximum from the seat wall.
Or for answers to.
For information about the ada including the revised 2010 ada regulations please visit the department s website www ada gov.
The seat must be folding installed on the side wall adjacent to the controls and shall extend from the back wall to a point within 3 of the shower entry.
Benches shall have seats that are 42 inches 1065 mm long minimum and 20 inches 510 mm deep.
For both ada transfer showers and ada roll in showers either a rectangular or l shaped seat may be used.
Benches shall comply with 903.
There must also be enough knee and toe clearance beneath the table measuring 27 in height 30 in width and 19 in depth.
Clear floor or ground space complying with 305 shall be provided and shall be positioned at the end of the.
Specific questions call the toll free ada information line at 800 514 0301 voice or 800 514 0383.
Ada standards for accessible design can be downloaded from www ada.
The department of justice published revised regulations for titles ii and iii of the americans with disabilities act of 1990 ada in the federal register on september 15 2010.
The seat shall be capable of secure placement.
903 2 clear floor or ground space.
Permanent seats at the head end of the bathtub shall be 15 inches 380 mm deep minimum and shall extend from the back wall to or beyond the outer edge of the bathtub.