30 inch by 48 inch access to the sink the door can t swing into this rectangle.
Ada restroom door handle height.
This guide explains scoping and technical requirements for accessible entrances doors and gates in the ada standards.
Effort to operate doors 8 5 pounds at exterior doors and 5 pounds at interior doors door hardware height 30 44 above floor.
Size min 3 0 wide 32 clear when 90 open and 6 8 in height.
The americans with disabilities act ada of 1990 includes specific guidelines for the construction of accessible or ada compliant bathrooms.
Handles pulls panic bars.
Toilet stall doors including door hardware shall comply with 4 13.
They can also serve as a general guide for safe user friendly accessible design when ada compliance is not required.
Figure 30 a standard stall.
Door hardware operable with a single effort without requiring ability to grasp hardware.
Door and gate hardware 404 2 7 the most important aspect of this section is the mounting height for operable parts pulls handles etc they need to be a minimum of 34 and a maximum of 48 above the finished floor.
These design requirements must be met for most public and commercial bathrooms.
If toilet stall approach is from the latch side of the stall door clearance between the door side of the stall and any obstruction may be reduced to a minimum of 42 in 1065 mm.
Hardware required for accessible door passage shall be mounted no higher than 48 in 1220 mm above finished floor.
According to the 2010 update to adaag the basic ada guidelines for a single user restroom are.
Door handles pulls latches locks and other operating devices shall be installed 34 inches 864 mm minimum and 48 inches 1219 mm maximum above the finished floor.
Door hardware ada compliant locks exit devices handles pulls latches and other operable parts on doors shall comply operable parts of such hardware shall be 34 inches minimum and 48 inches maximum above the finish floor or ground.
Minimum number at least 60 of public entrances must be accessible in new construction in addition to entrances directly serving tenancies parking facilities pedestrian tunnels and elevated walkways.
If a door has a closer then the sweep period of the closer shall be adjusted so that from an open position of 70 degrees the door will take at least 3 seconds to move to a point 3 in 75 mm from the latch.
In the previous edition of the ada standard section 4 13 9 included this statement.
The 2010 ada standards for accessible design effective 03 15 2012 include an important change relative to the mounting height of hardware.