2 the height of water closets should be between 11 17 to the top of the seat 3 the outlet of the toilet paper dispensers should not be mounted lower than 14 and no higher than 19 4 the top of the gripping surface at grab bars for children should be mounted between 18 27 a f f.
Ada grab bar height round toilet.
Two grab bars shall be installed on the back wall one located in accordance with 609 4 and the other located 8 inches 205 mm minimum and 10 inches 255 mm maximum above the rim of the bathtub.
However ansi allows for 6 mm projection in the allowed.
The toilet paper dispenser shall be mounted below the grab bar at a minimum height of 19 inches 485 mm.
Refer ada section 609 4.
19 water closet flush control max.
Side wall the side wall grab bar shall be 42 inches 1065 mm long minimum located 12 inches 305 mm maximum from the rear wall and extending 54 inches 1370 mm minimum from the rear wall.
Example single user toilet room.
Reach height and the 12 min.
Toilet grab gars.
Side wall rear wall rear wall the rear wall grab bar shall be 36 inches 915 mm long minimum and extend from the centerline of the water.
Toilet room fixtures and accessories.
Each grab bar shall be installed 15 inches 380 mm maximum from the head end wall and 12 inches 305 mm maximum from the control end wall.
Grab bars in toilet stall requirements.
Example of compliant heights to highest operable parts.
The height of the toilet seat shall be 17 to 19 inches 430 485 mm above the finished floor.
Toilet seat cover dispenser 6.
Diaper changing stations 5.
Clearance above the grab bar.
Water closet height min.
A 42 inches 1065 mm minimum length grab bar is required on the side wall spaced a maximum of 12 inches 305 mm from the back wall and extending a minimum of 54 inches 1370 mm from the back wall at a height of 33 36 inches 840 915 mm.
Side wall the side wall grab bar shall be 42 inches 1065 mm long minimum located 12 inches 305 mm maximum from the rear wall and extending 54 inches 1370 mm minimum from the rear wall.
Grab bars 1 1 4 o 1 1 2 o mounted at 33 above floor with 1 1 2 wall clearance.
Recessed dispensers are allowed within the 12 305 mm space above and 1 38 mm space below and at the end of a grab bar for ada the recessed dispenser must be flush.
Towel sanitary napkins and waste receptacles max.
A 42 inches 1065 mm minimum length grab bar is required on the side wall spaced a maximum of 12 inches 305 mm from the back wall and extending a minimum of 54 inches 1370 mm from the back wall at a height of 33 36 inches 840 915 mm.
Toilet paper dispenser 8.
See also ada requirements for seats grab bars in toilet stall requirements.
The toilet paper dispenser shall be mounted below the grab bar at a minimum height of 19 inches 485 mm.
Hand dryer of paper towel dispenser 3.