Consult your local ahj for opening force requirements pertaining to fire rated doors.
Ada door handle height requirements.
Figure 30 a standard stall.
Operable parts shall be operable with one hand and shall not require tight grasping pinching or twisting of the wrist.
Door handles pulls latches locks and other operating devices shall be installed 34 inches 864 mm minimum and 48 inches 1219 mm maximum above the finished floor.
Requirements for door handle ada compliance.
Hardware required for accessible door passage shall be mounted no higher than 48 in 1220 mm above finished floor.
In the previous edition of the ada standard section 4 13 9 included this statement.
Thresholds at doorways shall not exceed 3 4 in 19 mm in height for exterior sliding doors or 1 2 in 13 mm for other types of doors.
In california the minimum to maximum distance from the aff.
Door gate surfaces 404 2 10 in order for your customers in wheelchairs to easily be able to open doors and gates they must have a smooth surface that runs the full width of the door gate on the push side.
Clearance and maneuvering width is vital to the structural layout of a building but the ada doesn t stop there.
The 2010 ada standards for accessible design effective 03 15 2012 include an important change relative to the mounting height of hardware.
Handles pulls panic bars.
Raised thresholds and floor level changes at accessible doorways shall be beveled with a slope no greater than 1 2 see 4 5 2.
In addition to the components we ve covered there are also extensive ada door handle requirements laid out in the legislation.
Minimum number at least 60 of public entrances must be accessible in new construction in addition to entrances directly serving tenancies parking facilities pedestrian tunnels and elevated walkways.
This surface should be a minimum of 10 above.
Door hardware mounting heights 2010 ada changes.
These rules are in section 404 2 7 of the ada itself.
Ada door handle requirements.
If toilet stall approach is from the latch side of the stall door clearance between the door side of the stall and any obstruction may be reduced to a minimum of 42 in 1065 mm.
The margin of height is 38 inches minimum to a.
Door hardware ada compliant locks exit devices handles pulls latches and other operable parts on doors shall comply operable parts of such hardware shall be 34 inches minimum and 48 inches maximum above the finish floor or ground.
Comprehensive door handle and hardware requirements have been hard to find and even harder to interpret.