The measurement should begin where the disabled person has a 9 inch vertical clearance for the feet and approximately 27 inch clearance for the knees.
Ada commercial bathroom door requirements.
Doorways shall have a minimum clear opening of 32 in 815 mm with the door open 90 degrees measured between the face of the door and the opposite stop.
34 or 36 lever type hardware with lock 34 48 above floor.
Hallways and walkways should provide at least 80 inches of clear head room he says.
Door closers often require more than 5 pounds of force to open and the last thing you need if you re in a hurry to get there is to be hindered by a door that s too heavy to open ada compliance misconceptions.
Counters with a cash register require a section of the counter must be at least 36 long and not more than 36 inches above the floor.
The ada reception desk requirements include.
In a corner handicap stalls require a minimum of 60 x 60 compartment and is required with a minimum door size of 32 and the maximum size and more common is the 36 door.
Handles pulls panic bars door hardware ada compliant locks exit devices handles pulls latches and other operable parts on doors shall comply operable parts of such hardware shall be 34 inches minimum and 48 inches maximum above the finish floor or ground.
Grab bars must have round edges and must return to the wall or another anchor point so there are no exposed ends.
There are many other ways to make your restrooms and the areas around them more accessible and to ensure ada compliance spear points out.
Keep in mind that the door can swing into this rectangle.
For commercial bathrooms with multiple toilet stalls and handicap the rules change a little.
Larger person in larger wheelchair may need larger doorway ex.
Recessed fixtures can save space where two rooms are paired.
Doorways should be at least 32 inches wide with the door open at 90 degrees.
Grab bars must be installed between 34 and 38 inches above the floor and there must be a separation between the grab bar and the wall surface of at least 1 1 2 inches.
If a lavatory or other fixture is recessed next to a water closet the rear grab bar can be 24 instead of 36 long minimum centered on the unit if wall space does not allow a grab bar 36 long min.
Sales and service counters require a counter that is least 36 long and not more than 36 above the floor.
The bar must be 1 1 4 to 1 1 2 inches in diameter.
There must be a 30 x 48 access to the sink.
Main door to bathroom minimum of a 32 clear opening note.