Low energy swinging doors are governed by ansi 156 19 and ada and include these features and requirements.
Ada automatic door operator requirements.
Under ada the actuator must be located between 1 and 5 feet from the door.
Ada accessibility should not only be looked at as simply a design for disability but also a function to serve everyone that uses the facility.
Such doors shall not open to back check faster than 3 seconds and shall require no more than 15 lbf 66 6n to stop door movement.
4 13 12 automatic doors and power assisted doors.
In most cases automatic door operators are the best option to provide ada accessibility and ensure that a door closes.
If an automatic door is used then it shall comply with ansi bhma a156 10 1985.
It must also be placed so that a person using the actuator will not be within the path of a swinging door.
Minimum number 206 4 at least 60 of public entrances must be accessible in new construction in addition to entrances directly serving tenancies parking facilities pedestrian tunnels and elevated walkways.
It must be accessible from both sides of the door whether the door is open or closed.
Typically it may only be necessary to equip one door in a bank of doors.